Eagba(m): 1:46pm On Apr 30, 2024 |
bassdow:boss can I use s for charging phones direct |
dollarnaira: 2:27pm On Apr 30, 2024 |
Eagba: 100% possible. But only sunlight. Days of rain na bad market. Ran a rechargeable fan with it yesterday without battery. |
ayo1984: 2:34pm On Apr 30, 2024 |
Please house how reliable is pow Mr 80a solar charge controller
|
mctfopt: 2:37pm On Apr 30, 2024 |
Dam5reey: That's impressive to see that high VoC of the MPPT and low starting voltage. Most high input voltage inverter requires high starting voltage to run the MPPT controller. |
mctfopt: 2:41pm On Apr 30, 2024 |
ayo1984: Used the 60A. Not bad. |
Eagba(m): 2:42pm On Apr 30, 2024 |
dollarnaira:Ok . Like what wattage of is advisable for an average of 25 phones charging simultaneously. Later she can get batteries |
Eagba(m): 2:44pm On Apr 30, 2024 |
dollarnaira:Ok . Like what wattage of is advisable for an average of 25 phones charging simultaneously. Bros what kind of controller will be needed to avoid damaging phones Later she can get batteries . |
bassdow: 2:45pm On Apr 30, 2024 |
Eagba:what you mean by "DIRECT" ? If you mean by connecting the phone directly to solar , without any thing in-between, then it's a NO |
Eagba(m): 2:55pm On Apr 30, 2024 |
bassdow:what can I connect in between |
obitobe: 3:04pm On Apr 30, 2024 |
Sapiosexuality: please use your old charge controller and leave out the in-bult charge controller 1 Like |
ayo1984: 4:09pm On Apr 30, 2024 |
mctfopt: Thank you sir |
odimbannamdi(m): 4:13pm On Apr 30, 2024 |
dollarnaira: How did you do the connection? |
Dam5reey(m): 4:18pm On Apr 30, 2024 |
Eagba: You want to charge 25 phones simultaneously, that's 250 watts of energy if each phone takes 10w. that's base charging 2A 5V. Plan at least a small battery to serve as a buffer for cloudy periods. Plan for LFP backup 12V, 50AH, or lead acid 12V 100AH will do for a start. 500w Sachet inverter, you can't run DC-DC due to the number of phones. 12V 60A PWM charge controller, 2PC of 180W Solar . with 500K you will reach somewhere! 1 Like |
chris81964(m): 4:52pm On Apr 30, 2024 |
RickyM(m): 5:05pm On Apr 30, 2024 |
Good evening to y’all great people Please I’m curious about something and I hope y’all can clarify it. What should be the battery full voltage and low battery of a 24V LiFePO4 battery pack? Due to my knowledge, I thought each cell can attain 3.65V at fully charge and 2.5V while low? |
isangjohnson: 5:40pm On Apr 30, 2024 |
RickyM:The allowable voltage range that will not harm the cells is 2.500v-3.650v. The working voltage range is 3.000v-3.400v per cell. Charging above 3.425v per cell gains you nothing other than tear and wear because there is no appreciable stored energy above that voltage. 6 Likes 1 Share |
isangjohnson: 6:00pm On Apr 30, 2024 |
Sapiosexuality:To the best of my knowledge, there is no specific time or duration. Some may last for two months, some may last for one year, some may last for five years and some may still last beyond ten years. The durability depends on many factors including the quality of the products and the maintenance culture of the end . 1 Like |
bbally: 6:12pm On Apr 30, 2024 |
Dam5reey: It is true that with 30v the inverter will solar input but the spec design and requirements for these high voltage inverters differs from model to model. Yours might require 120v for nominal operation but his inverter requires best nominal volt of 240v. Correct me if am wrong, we are all here to know more. See attached
|
durodee(m): 6:37pm On Apr 30, 2024 |
Sapiosexuality:Like for many inverters or electronics it depends on many factors- Quality of the inverter itself, protection provided at installation against grid surge, lightning strikes, types of loads its being used for, ambient temperature, duration of use etc. The worst hybrid I have used so far (SOROTEC 5KVA range) lasted about 3 months before suddenly packing up, most will last years but unless you are using the high end types, I will budget 2-4 years on average before you have to repair something . The National grid with its "dirty" voltage and current is a major enemy. Off grid, the worst enemy is the element- heat/fan stoppage , lightning strike etc, etc 1 Like |
Eagba(m): 7:05pm On Apr 30, 2024 |
Dam5reey:Thanks , but remove the battery in this equation. Is there a way around? Let cloudy day be cloudy. 1 Like |
isangjohnson: 7:19pm On Apr 30, 2024 |
durodee:Apart from the quality of products, which may be a factory designed fault, every other thing you listed here is the false of the end s. Take a look at the heating temperature of the inverter via the attached picture. Very few people do create time to open the sides of their inverter and clean the dust/blockage. Some people do not even it till they pack the inverter. This blockages do not always create room for air circulation/ventilation inside the system as the fans are blowing, whereby creating unnecessary internal heat within the closed system.
|
Penuelseun(m): 9:58pm On Apr 30, 2024 |
isangjohnson:There is still energy stored over 3.425v, I normally stop charging at 3.450v |
zeestone99(m): 10:57pm On Apr 30, 2024 |
isangjohnson: We have bad maintenance culture but we won't agree. There are also some cases of factory error. |
ojeysky(m): 2:26am On May 01, 2024 |
48v 280AH cells with complete custom box and 200A JK BMS available for sale. Price options: 2.9m (coupling inclusive) 2.650m (buyer couple himself) Unit 280AH cells available @138k (minimum 8 units) in my signature. Call/WhatsApp 1 Like |
Parser: 3:54am On May 01, 2024 |
kwende: Depends on your load. Mostly 5 to 6kw inverter. Next question should be choosing between transformer based inverter or chopper based? Cause 5M no b small money, @bassdow @bigbrovar and other experts make una pls come give expert advice. Anyone with experience with transformerless using iron and AC for like 2yrs no issues.... |
ojeysky(m): 6:01am On May 01, 2024 |
kwende: Your 5m should get you the following: 48v 280AH lifepo4 battery 5kw Growatt or SMS hybrid inverter 6x580w jinko Connection accessories Installation workmanship 2 Likes |
HeavenlyBang(m): 7:54am On May 01, 2024 |
ojeysky: SMS ![]() |
ojeysky(m): 8:16am On May 01, 2024 |
primeelectronix: 8:32am On May 01, 2024 |
AUTHORIZED DEALER ON JINKO SOLAR S,GROWATTS INVERTER AND PYLONTECH LITHIUM BATTERIES GET YOUR ORIGINAL JINKO S AT THE BEST RATE EVER.. AVAILABLE S RIGHT NOW ARE JINKO 440WATTS@130,000 JINKO 550 WATTS @155,000 JINKO 555WATTS @160,000 JINKO 580 WATTS @ 175,000 WHY RUN TO ALABA AND ARENA..WE ARE HERE TO HELP EASE THE STRESS OF DELIVERING SOLAR AND INVERTERS WE CAN DELIVER WITH LAGOS,OYO,OGUN,ILORIN,EDO,DELTA ,ANAMBRA, IMO,PH AND MORE. SEND IN YOUR ORDERS TO WHATSAPP 09074488146 GET YOUR BEST RATE ON MORE QUANTITY.. |
isangjohnson: 8:40am On May 01, 2024 |
ojeysky:I prefer Felicity to SMS 2 Likes |
HeavenlyBang(m): 8:42am On May 01, 2024 |
ojeysky: SRNE is a quality middle ground. They're the biggest Chinese inverter makers, I think. It's their budget models that companies like Powmr and Easun rebadge. |
Danibestguy: 8:49am On May 01, 2024 |
Hello. I have a 24v 100ah lifepo4 battery. Constant load - 240w which is just a fridge and a fan. I want to get an inverter to match it. I'm also planning on getting s later on. Please note that we get up to 8hrs of grid light daily. Is it advisable to get an hybrid inverter ? Considering that I'm staying in a rented apartment(limited space), will 2 500/550w s in series be enough? Budget is 500k. |