Solar Energy, A Complement To FTA (2775474 Views)
jonescosmos(m): 12:11pm On Apr 10, 2024 |
Mavor: 2x 8KW Deye Hybrid Inverters EU-Version. 4x 15KW Felicity LPBF48300 Battery Packs. 16x 600W Canadian Solar s. 10x 540W Felicity Solar s. 8x 625w Jinko Solar s (to be added this weekend) Installation is almost 2 years old. Try to use present market prices to cost it incase you are considering a similar setup. 7 Likes |
brightk(m): 12:18pm On Apr 10, 2024 |
jonescosmos:affordability n immediate are things installers consider wen tins go south.. |
Mavor: 12:20pm On Apr 10, 2024 |
jonescosmos:Omo!!! This one na power plant ooo!!! |
kristien4(m): 12:28pm On Apr 10, 2024 |
2x 8KW Deye Hybrid Inverters EU-Version. 4x 15KW Felicity LPBF48300 Battery Packs. 16x 600W Canadian Solar s. 10x 540W Felicity Solar s. 8x 625w Jinko Solar s (to be added this weekend) Installation is almost 2 years old. Try to use present market prices to cost it incase you are considering a similar setup.[/quote] Abeg where u see space for roof take install all these s?? And secondly...where u see money..lol 1 Like |
jonescosmos(m): 12:49pm On Apr 10, 2024 |
brightk: If prerequisites are bean respected and checked out before installation, the only you will be giving to your clients is to go and blow off dusts from the units, washing the solar s, etc. There would be absolute no need for anything to go south. Installers that will not insist that their clients do proper earth, load separation, install voltage and surge protectors, install fuses and breakers, use the appropriate wire guages, conduct energy survey at clients property, etc. That installer is bound to attract arguments or quarrels afterwards. 7 Likes |
Iinnov8: 12:57pm On Apr 10, 2024 |
Flash sale 2 units of original 160ah Fullriver FAT (Front Access Terminals) batteries for sale Background information Batteries were commissioned as 12v in February 2022 and immediately hooked up to solar and ed with grid charging using Suoer 12v battery charger. Batteries were optimally charged everyday and it was hardly used below 12.0v (equivalent to 50% DoD) before another cycle of charge begins. Batteries were decommissioned in December 2023 and was occasionally trickled-charged to prevent sulphation Based on the load test I just performed on the batteries using the energy-efficient EASun satchet inverter on a load of 130w (just a 55" Hisense smart TV) it gave a backup time of 6hours before hitting 12.0v from full charge. I project another 4hours before the battery gets completely drained. If you are looking to power a staggered load of lights, standing fan and laptop (all below 70w), this will give you good value for money. Batteries will come with a free DC voltage meter that gives an independent voltage reading and a defective PowMr 60A MPPT solar charge controller. Controller was wrongly connected at one of the battery terminals and it blew. I can refer you to someone who can fix it Price: 250,000 firm. Waybill is welcomed
|
HeavenlyBang(m): 1:29pm On Apr 10, 2024 |
jonescosmos: Pricier than I expected 🙃 Looking for 3-3.5KW inverter under 400k. |
TechGeek777: 2:01pm On Apr 10, 2024 |
jasp12: Batteryless inverter also requires that you get small battery bank to during raining season and bad weather conditions |
TechGeek777: 2:12pm On Apr 10, 2024 |
Mavor: 5.5kw pv & max 10kwh battery are more than enough. Just power your AC by 11:30am and put it off by 4:30pm. Use timer to time the AC to run for 3hrs (9pm - 12am) and your battery should carry you till next day. In RE management is the key. 1 Like |
Ferdiwar: 2:42pm On Apr 10, 2024 |
Please has anyone used Longi s? How can it be compared to jinko s? I'm currently working on increasing my s and torn between Longi 580w and either Jinko 580w or 625w, but wants to know how Jinko s performs. |
swagifted(m): 2:53pm On Apr 10, 2024 |
brightk:not all installers are the same sha....some clients no de carry ear hear say e de affordable... |
apexquest(m): 3:58pm On Apr 10, 2024 |
Obnoxious2001: Please Hit me up on 08060346648 (WhatsApp/call) |
mctfopt: 4:04pm On Apr 10, 2024 |
Ferdiwar: Interesting concept. |
mctfopt: 4:06pm On Apr 10, 2024 |
Ferdiwar: I've used Longi. The 450w version. Performance was superb and on par with Jinko. |
mctfopt: 4:09pm On Apr 10, 2024 |
jonescosmos: If you are in a country with a smart metering system, PHCN or whatever they like to call themselves now, would be owing you so much power as the excesses which you are bound to generate would go back to the grid. A friend living in NJ, US pays less than $1000 as total electricity per year courtesy of his solar setup. 1 Like |
munchies: 4:14pm On Apr 10, 2024 |
Can bad earthing system cause an output short circuit?
|
tivta(m): 4:18pm On Apr 10, 2024 |
jonescosmos: Thank God a felicity . Please how are the batteries performing? What DOD do you run the batteries down to? What is the expected cycle rate? |
munchies: 4:22pm On Apr 10, 2024 |
mctfopt: Please can you break this down in lay for better understanding ? I know someone that want inverter to power ice block machine . Is lithium the best to use? |
jasp12(m): 4:39pm On Apr 10, 2024 |
TechGeek777: Ok thanks |
Mavor: 4:45pm On Apr 10, 2024 |
TechGeek777:Thank you. |
ojesymsym: 5:15pm On Apr 10, 2024 |
I have been in this situation before, what I had to do was charge the batteries without the BMS to bring up the voltage above the cutoff point, after which I was able to turn it back on on the app. Sometimes it is that straight forward, sometimes it is not. When it is not, I lose track of what eventually I did to make it work but just know that when you get the voltage up, everything else you now need to do is within the app itsellf auwal8377: |
jonescosmos(m): 5:16pm On Apr 10, 2024 |
mctfopt: Oh yes. You are right. I'm sure we will get there soon. |
Kreamie(m): 5:39pm On Apr 10, 2024 |
We're not here yet. ![]() mctfopt: |
jonescosmos(m): 5:48pm On Apr 10, 2024 |
munchies: In some scenarios yes it can. Some inverters don't accept grounding DC and AC Circuits to the same rods. They will trigger error of current leak and that's gonna shut down the output of the inverter. I have come to realize that the best practice of grounding Hybrid Inverters is to drive down two rods at the same spot like 15cm apart 10ft below earth surface. Use one for DC circuits and one for AC circuits. Now before them earth professionals come at me for this. It's been approved by NEC. It has also recently saved my ass just last week here ooo. Finished installation and inverter started tripping at Error F23 (Deye 8kw) until I separated the AC Earth Rod and buried another earth rod same location and used it as DC earth rod. 1 Like |
RickyM(m): 5:58pm On Apr 10, 2024 |
Good evening to great Nairalanders🫡🫡🫡 Please I need y’all opinion on this‼️‼️ Does any of these PWM charge controller good for charging LiFePO4 battery? Or any other suggestions but not MPPT abeg because man no guide 😂😂😂
|
jonescosmos(m): 6:01pm On Apr 10, 2024 |
tivta: Batteries are doing great so far. I have done upto 90% DOD with them batteries. Last time I checked, they had like 35, 46, 35, 60 cycles respectively. They are expected to reach the 6000 cycles as d. 2 Likes |
isangjohnson: 6:02pm On Apr 10, 2024 |
jonescosmos:The LG Dual Inverter does not have this display, but is can be chilling @ 16°C with less than 600w power depending on the AC capacity and the ambient temperature. From my battery monitor, after turning off the pv input, my 1.5hp dual inverter AC was turned on @ 16°C with the existing loads of 206w at 4:06pm. The power consumption rises to 1,057w at 4:11pm before dropping to 460w at 4:18pm maintaining the cooling. The consumption used to be higher than this when the ambient temperature is higher. Apart from the actual power consumption of the AC, the ambient temperature also affect the consumption.
|
jonescosmos(m): 6:05pm On Apr 10, 2024 |
RickyM: None of these toys are LiFePo4 compatible. Why are they still even selling these toys in Nigeria huh? People should stay away from these toys please. No offense to the sellers. 5 Likes |
RickyM(m): 6:07pm On Apr 10, 2024 |
jonescosmos: Any suggestion on which one to buy? 6units of 300W to be connected to it in parallel |
ojesymsym: 6:07pm On Apr 10, 2024 |
Why does Deye use KW and not KVA? What is the real KVA of these KW inverters? jonescosmos: 1 Like |
isangjohnson: 6:09pm On Apr 10, 2024 |
isangjohnson: 1 Share |
RickyM(m): 6:54pm On Apr 10, 2024 |
[quote author=isangjohnson post=129369719][/quote] Do you think this is more efficient than Thermocool Genpal series? 1 Like |