Your soakaway can be designed and built in such a way that it can vehicular load conveniently without failing. dapotemi: |
![]() |
Project picture
|
![]() |
Pic
|
![]() |
More warehouse picture
|
![]() |
Happy Sunday everyone
3 Likes |
![]() |
Casting of column bases
|
![]() |
It is a cantilever beam or slab? The depth, the position and size of the rebars of the structural member must be adequate enough to the expected load. Pclemenza: 3 Likes |
![]() |
Placement of column starters rebars
|
![]() |
It is possible to have such design without any fear of collapse, if it is properly designed by a structural engineer and also constructed as designed cos the weight of the roof : trusses and covering would have been taken into consideration during the design stage. For such cantilever beams, the size and position/placement of the reinforcement bar is very important in order to adequately the load it would be subjected to without any deflection or failure. If your engineer has done the right thing then there is nothing to be worried about. Celepope: 1 Like |
![]() |
Good morning all. Enjoy your day |
![]() |
Blinding of column bases
|
![]() |
The foundation types are pad and strip footings Excavation of trenches
|
![]() |
Setting out of building
|
![]() |
Site clearing
|
![]() |
An experienced/qualified safety officer is urgently needed at a construction site in Ogun state. Send your application to [email protected] |
![]() |
We are constructing an electrical control room .. us as we share the construction process.. |
![]() |
Happy new month everyone. This month of August shall favour us and there shall be no lost. 1 Like |
![]() |
An experienced/qualified safety officer is urgently needed at a construction site in Ogun state. Send your application to [email protected] |
![]() |
Sad. They should do an autopsy to determine the actual cause of her death.
11 Likes 1 Share |
![]() |
Happy new month everyone
|
![]() |
Happy new month everyone
|
![]() |
Wonder working power
2 Likes |
![]() |
We are only responsible for the civil works not fabrication of tanks michlins: |
![]() |
Yes. michlins: |
![]() |
|
![]() |
Ring beams for large storage tanks
3 Likes |
![]() |
I do not additional floor(s) during construction stage without structural redesign and checks to confirm the suitability of the . However since this floor is to the solar s only , you don’t need 20mm bars for the columns, instead use 16mm as your second to roof level columns reinforcements and also ensure that you stiffen the s with reinforced concrete beams. Let your structural engineer design the roof slab and beam, the thickness of your slab should be at least 150mm (6inches) or as designed by the engineer. Chichilas: 1 Like |
![]() |
Ring beams construction for above ground large storage tank
|
![]() |
This concrete wall has failed, i suggest you break it off and do a new one well reinforced, with adequate thickness and good mix ratio. speak2bella: 2 Likes |
![]() |
Do a soil test to confirm the nature of your subsoil and also know the appropriate foundation type. However, the final height of your foundation should be determined by the road level to avoid flood of your TeetoBolt: |
![]() |