waleayeni1: 9:05am On Feb 27
waleayeni1:
Good evening experts,
Please which inverter would be best for my home usage out of Schneider SW4024 & SW4048? Also, what's they minimum capacity of LiPo4 battery bank that would be required? Are these inverters hybrid?

Please is there any reason why no one is looking at my question? If i offend make una forgive. Please help.
Valto(m): 9:10am On Feb 27
swagifted:
competition on fire....lets continue till we get back to 15kwh for 1.5million naira and less....i know we can do it...everybody should continue to patronise the naira till we hit 1k naira per dollar ...patronise MRS filling stations
my 48v 15kwh made with 16pcs brand new EVE 280K V3 cells and JK 200A 2A active balancer inverter Bluetooth bms with communication ports, JK 3.2inch display , 4pcs 200A pure copper battery terminals , 200A DC MCCB circuit breaker , sturdy metal box with wheel tyres is 2.3M , price still negotiable ......

9 Likes 2 Shares

HeavenlyBang(m): 10:14am On Feb 27
waleayeni1:


Please is there any reason why no one is looking at my question? If i offend make una forgive. Please help.

Probably because most people here don't have hands-on experience with Schneider hardware.

2 Likes

burnerr: 10:41am On Feb 27
solasola:


Its better you share pictures of the display.
Is there communication between your inverter and the battery, error 04 should be low battery though..... Follow the advice given on setting up protocol 05, and make sure the communication cable is connected correctly, i mean. There is a particular end that goes to the inverter and battery, if interchanged, it wont connect. Hope this helps a little.
So I spoke with fouani and they said to use L52. I'm still getting the error and here's a picture

burnerr: 10:57am On Feb 27
solasola:


Its better you share pictures of the display.
Is there communication between your inverter and the battery, error 04 should be low battery though..... Follow the advice given on setting up protocol 05, and make sure the communication cable is connected correctly, i mean. There is a particular end that goes to the inverter and battery, if interchanged, it wont connect. Hope this helps a little.
Any idea if this could be caused by the earthing? Cause the installer didn't setup earthing for the battery.
Christian8880: 11:27am On Feb 27
All wattages of Jinko solar s still available at good price.
Call or WhatsApp me on 09116033581

waleayeni1: 11:45am On Feb 27
HeavenlyBang:


Probably because most people here don't have hands-on experience with Schneider hardware.

Thank you for dignifying my question with an answer. May Jehovah God reward you accordingly.
mctfopt: 12:07pm On Feb 27
waleayeni1:
Good evening experts,
Please which inverter would be best for my home usage out of Schneider SW4024 & SW4048? Also, what's they minimum capacity of LiPo4 battery bank that would be required?


I have a 4048, will advise you to get that instead of the 24 version (4024) simply because it's easier to run high capacity lithium battery in 48v instead of 24v. Both are same capacity though just different battery system voltage.

Also you get to run higher number of solar s in 48 configuration rather than 24v with same solar charge controller.

There is no "minimum number" in battery configuration. You buy battery according to your load needs. You can get a 500wh lithium battery in both 24v and 48v. Same inverter can also work with a 60000wh or 60kwh battery.

Using generator analogy, your inverter is the generator, your battery is the petrol. The amount of fuel you buy is dependent on how long you plan to use the generator. This is applicable to inverter too, size of battery depends on the load to be powered and the duration you want it powered.

waleayeni1:


Please is there any reason why no one is looking at my question? If i offend make una forgive. Please help.


Here is a DIY thread, s here often reply to posts they have experience in or interested in. No one will deliberately ignore a post made by a . Also no one here is paid to reply messages so reply may be slow. Cheers.

8 Likes

Christian8880: 1:21pm On Feb 27
Brand new 320w AFRICELL solar s available in unit and bulk
Price #80,000

Call or WhatsApp me on 09116033581

Iinnov8: 4:20pm On Feb 27
TSHIRT2:

I can testify to the assertion that this inverter can power many appliances.
I have the 3000w which I currently use to pump my 0.75hp submersible pump .

Just seeing this. Thanks so much got sharing your . Much appreciated
Iinnov8: 4:21pm On Feb 27
Take all four 30A PWM charge Controller for 20k firm

Iinnov8: 9:35pm On Feb 27
A major question we understandably get asked most times by prospective customers regarding our battery is "what is inside/what is it made of".

So, in this video, we unveil the inside of the PowMr 12.8v 100ah LiFePO4 (Lithium) battery


https://www.youtube.com/watch?v=sJwdLMl1Vew

Critical summary from the test are as follows:

- Excellent assembly from the manufacturers using Rept Grade A battery cells marked with QR-codes that provides more details upon scanning
- All battery cells are connected using a JBD 100A BMS and appropriately sized cables and relevant components
- Sufficiently cushioned and held together to guard against falls and drops

Price: 298,000. Discount available if you buy more units
Call/Whatsapp: 0916-043-7395

Follow our thread for more updates:
https://nairaland.macsoftware.info/8194434/powmr-12.8v-100ah-lithium-lifepo4#131666946

1 Like

burnerr: 9:17am On Feb 28
sad sad day 3 of having this battery configuration issue. The battery is showing as low while the inverter reads 53.9V. I've tried everything I've seen online, and the shinewifi dongle isn't coming up at all when plugged to the inverter.

If anyone has any suggestions, I'm all ears.
jonescosmos(m): 11:05am On Feb 28
Please make sure you followed the instruction as stated on your manuals.
Secondly, It is advisable to always restart your Inverter and Battery when changing protocols.
I would recommend that you also get another patch cord (75cm Lan Cable) to swap out your communication cable and see if it resolves the issue.
Also make sure that your systems (Inverter and Battery) are properly grounded to avoid ESD damages which is common in this field.
If these does not fix the issue, Do it my style.

YANK BOTH THE INVERTER AND BATTERY TO YOUR VENDOR'S OFFICE AND HAVE THEM PROOVE TO YOU THAT EVERYTHING IS OK.

Yes because sometimes these devices may have a factory defects or damages inflicted during logistics and the supplier will always tell you that you might be doing it the wrong way. So I would swallow my pride, storm their office with the device and have them assemble it in their office and most times it turns out that i have been right all along, so they will try to convince you to turn it in for service.


burnerr:
sad sad day 3 of having this battery configuration issue. The battery is showing as low while the inverter reads 53.9V. I've tried everything I've seen online, and the shinewifi dongle isn't coming up at all when plugged to the inverter.

If anyone has any suggestions, I'm all ears.

waleayeni1: 12:05pm On Feb 28
mctfopt:



I have a 4048, will advise you to get that instead of the 24 version (4024) simply because it's easier to run high capacity lithium battery in 48v instead of 24v. Both are same capacity though just different battery system voltage.

Also you get to run higher number of solar s in 48 configuration rather than 24v with same solar charge controller.

There is no "minimum number" in battery configuration. You buy battery according to your load needs. You can get a 500wh lithium battery in both 24v and 48v. Same inverter can also work with a 60000wh or 60kwh battery.

Using generator analogy, your inverter is the generator, your battery is the petrol. The amount of fuel you buy is dependent on how long you plan to use the generator. This is applicable to inverter too, size of battery depends on the load to be powered and the duration you want it powered.




Here is a DIY thread, s here often reply to posts they have experience in or interested in. No one will deliberately ignore a post made by a . Also no one here is paid to reply messages so reply may be slow. Cheers.

I appreciate you taking out time to explain to me. Apologies if I sounded entitled. I'll keep what you have said in mind going forward. So it's the SW4048 for me then

1 Like

realpoacher(m): 12:22pm On Feb 28
Guys I need a modest quote for a max load of 600 watts for 5 hours daily.
I want a LiPo4 battery please.


I intend to charge the battery with solar and light (whenever NEPA is available).

Thanks
bkuranga(m): 12:40pm On Feb 28
HeavenlyBang:


12 hours.

Two jinko 555w s - 250k
Find a small 12v hybrid inverter to buy from brands like Sako, Welion, CWorth - 250k
Powmr 100aH battery -290k
Accessories and installation - 150k

Put the inverter in power saving mode so it doesn't invert if it doesn't detect a load, then buy a timer for the freezers.

You can run on solar from 8 am - 5 pm, which is 9 hours.

Set the timer to come on at midnight and go off by 3 am.

My ~200L chest freezer draws just 110w. Even a 300L freezer shouldn't take more than 150W. Two of them 300w. Three hours of use should have the battery down to about 25% of charge.

Twelve hours of runtime daily, and your freezers remains frozen for 24 hours.


Thank you once again.
So I revisited this, and I'm lost somewhere.


What capacity of hybrid inverter do you suggest?
I have searched, most that I have been seeing are 24V and not 12V.

1 Like

Valto(m): 12:54pm On Feb 28
realpoacher:
Guys I need a modest quote for a max load of 600 watts for 5 hours daily.
I want a LiPo4 battery please.


I intend to charge the battery with solar and light (whenever NEPA is available).

Thanks
24v 1.5kw hybrid inverter with 40A mppt +24v 2.5kwh lifepo4 lithium battery =810k

buy 2pcs of jinko 555w s from LG

1 Like

zeestone99(m): 1:13pm On Feb 28
Hello house.

Few pcs 100ah 12.8v LIFEPO4 BATTERY with inbuilt JBD 100a smart Bluetooth BMS.

Connect to your mobile app via Bluetooth.

Price - 290k (slightly negotiable) promo price.

Limited quantity available.

Call/chat - 08117398294

HeavenlyBang(m): 1:29pm On Feb 28
bkuranga:



Thank you once again.
So I revisited this, and I'm lost somewhere.


What capacity of hybrid inverter do you suggest?
I have searched, most that I have been seeing are 24V and not 12V.


Valto has 12v hybrids for sale.
Christian8880: 1:34pm On Feb 28
15kwh 51.2v Sms lithium batteries available
Price #2,050,000

Call or WhatsApp me on 09116033581

1 Like

bkuranga(m): 2:48pm On Feb 28
HeavenlyBang:


Valto has 12v hybrids for sale.

Okay, thank you.
I will reach out to him.
realpoacher(m): 2:58pm On Feb 28
Valto:
24v 1.5kw hybrid inverter with 40A mppt +24v 2.5kwh lifepo4 lithium battery =810k

buy 2pcs of jinko 555w s from LG

Is it plus the 555w s 800k or just the inverter and battery 800k?
realpoacher(m): 3:00pm On Feb 28
zeestone99:
Hello house.

Few pcs 100ah 12.8v LIFEPO4 BATTERY with inbuilt JBD 100a smart Bluetooth BMS.

Connect to your mobile app via Bluetooth.

Price - 290k (slightly negotiable) promo price.

Limited quantity available.

Call/chat - 08117398294

How much for 12v 200AH?
Nteogwuija(m): 3:40pm On Feb 28
Hi, guys. So I did a parallel connection of 3 350w s, with each having a maximum current of 13.6a. And I've noticed that whenever the sun is very high my DC breaker would go off and the system will stop charging. I'd have to turn it back on b4 it resumes charging.

The wire is a 4mm² coated wire.

Please, what do I have to change to rectify this?
maklelemakukula(m): 4:11pm On Feb 28
KA24DETT:


LOL.. thats not true. it will clip. I do run my 10kv hybrids with 33,000 watts of solar s connected. MPPT pulling 120amps from dawn to dusk. One year and still working. In my system, none of my systems have less than 30,000 watts of solar s attached to it and i have 8 systems running. I can attach videos.
That's nice and makes alot of sense, but I wouldnt like to void the warranty tho. Also there's no space in my place for 3x of the inverter's capacity in solar s to stay. Then the money again is another issue in present day Naija
maklelemakukula(m): 4:14pm On Feb 28
burnerr:
sad sad day 3 of having this battery configuration issue. The battery is showing as low while the inverter reads 53.9V. I've tried everything I've seen online, and the shinewifi dongle isn't coming up at all when plugged to the inverter.

If anyone has any suggestions, I'm all ears.
Ask them to send their tech person over.
Also, can you please share the quotation for the materials you eventually got for the installation ?
maklelemakukula(m): 4:20pm On Feb 28
burnerr:
sad sad day 3 of having this battery configuration issue. The battery is showing as low while the inverter reads 53.9V. I've tried everything I've seen online, and the shinewifi dongle isn't coming up at all when plugged to the inverter.

If anyone has any suggestions, I'm all ears.
Also, read this and follow up instructions carefully


Error 04: This indicates that the inverter detects the battery voltage or State of Charge (SOC) as too low. It could stem from an actual low battery voltage, a mismatch in settings, or a communication issue affecting voltage readings.

Error 20: This points to a BMS (Battery Management System) communication failure between the inverter and the Hope 5.5L-A1 battery, often due to incorrect settings, faulty cabling, or compatibility issues.

Since the Hope 5.5L-A1 is a Growatt branded battery, it should be compatible with the SPF 6000ES, but proper configuration is key to resolving these errors.

Recommended Configuration Steps
Here’s how to configure your system:

1. Physical Connections
Battery to Inverter: Ensure the battery power cables (positive and negative) are securely connected to the inverter’s battery terminals, with no loose connections or corrosion.
Communication Cable: The Hope 5.5L-A1 typically uses a CAN bus for BMS communication. Connect an RJ45 cable between the battery’s CAN port and the inverter’s BMS port. Use the cable provided by Growatt, as pin assignments matter (e.g., CAN-H and CAN-L must match).
Battery Breaker: Confirm the battery breaker is ON and the battery is outputting power.

2. Check Battery Voltage
Use a multimeter to measure the battery voltage at the terminals. The Hope 5.5L-A1 is a 48V nominal battery, so a healthy voltage should be between 48V and 54V (depending on SOC). If it’s below 42V, it may need charging via solar or grid before the inverter can operate properly.

3. Inverter Settings
Access the SPF 6000ES settings via the LCD display and buttons. Adjust the following parameters (refer to the SPF 6000ES manual for navigation):
Program 05 (Battery Type): Set to “LI” (Lithium) to enable BMS communication. Since the Hope 5.5L-A1 is a Growatt battery, select the appropriate lithium protocol:

Likely L01 or L03 (specific to Growatt ARK/Hope series). Check the battery manual or Growatt to confirm the exact protocol code for the 5.5L-A1.

Avoid “USE” or “US2” unless BMS communication fails entirely (more on this later).
Program 02 (Max Charging Current): Set to a safe value, e.g., 60A-100A, depending on your battery’s specs (Hope 5.5L-A1 typically s up to 100A charging).
Program 01 (Output Source Priority): Set to “SBU” (Solar-Battery-Utility) or “SUB” (Solar-Utility-Battery) based on your preference.
Program 12 (Battery Low Voltage Cutoff): Set to 42V-44V to prevent deep discharge.
Program 13 (Battery Back-to-Grid Voltage): Set to 48V-50V to ensure the battery charges adequately.
Program 19 (CV Charging Voltage): Set to 56.4V (default for most 48V lithium batteries, including Growatt’s).
Program 20 (Float Charging Voltage): Set to 54V or as recommended by the Hope 5.5L-A1 manual.

4. Test BMS Communication
After setting Program 05 to “LI” with the correct protocol, restart the inverter by turning it off and back on.
Check the LCD for battery SOC and voltage readings. If Error 20 disappears and SOC displays correctly, communication is established.

5. Troubleshooting Errors

If errors persist:
Error 04 Persists:
The battery may be too discharged. Charge it externally (via solar s or a charger) until it reaches at least 48V, then reconnect.
the inverter’s voltage reading matches your multimeter. If not, there may be a wiring issue or inverter fault.

Error 20 Persists:
Double-check the RJ45 cable integrity. Swap it with a known working cable if possible.
Ensure the battery’s firmware and inverter’s firmware are up to date and compatible. Growatt for the latest firmware if needed.
As a fallback, set Program 05 to “US2” (-Defined without BMS). This disables BMS communication and relies on voltage-based control. Adjust Programs 19 and 20 as above, but this is less optimal for battery health.

6. Additional Checks
Battery Health: If the Hope 5.5L-A1 has been deeply discharged repeatedly, it might be in a protection mode. Reset it per the battery manual (usually involves turning it off/on or pressing a reset button).
Inverter Logs: Review the inverter’s fault log (if accessible) for more context on when Errors 04 and 20 trigger.

Next Steps
Try these steps and monitor the system. If Errors 04 and 20 still occur, let me know:
The exact battery voltage you measure.
Whether the BMS communication works after setting “LI” with the correct protocol.
Any additional behavior (e.g., inverter shutting down, alarms).
This should resolve the issue, but if not, we can dig deeper into hardware or firmware causes. Let me know how it goes!

1 Like

kristien4(m): 4:23pm On Feb 28
burnerr:
sad sad day 3 of having this battery configuration issue. The battery is showing as low while the inverter reads 53.9V. I've tried everything I've seen online, and the shinewifi dongle isn't coming up at all when plugged to the inverter.

If anyone has any suggestions, I'm all ears.
(1)Connect from battery PCS port to inverter BMS port
(2) Use protocol L51
(3) Your dipswitch settings, number 1 should be on why 234 should be off.
This is how i connected my growatt hope battery to my Growatt Inverter and it works well.

2 Likes

kristien4(m): 4:25pm On Feb 28
maklelemakukula:

Also, read this and follow up instructions carefully


Error 04: This indicates that the inverter detects the battery voltage or State of Charge (SOC) as too low. It could stem from an actual low battery voltage, a mismatch in settings, or a communication issue affecting voltage readings.

Error 20: This points to a BMS (Battery Management System) communication failure between the inverter and the Hope 5.5L-A1 battery, often due to incorrect settings, faulty cabling, or compatibility issues.

Since the Hope 5.5L-A1 is a Growatt branded battery, it should be compatible with the SPF 6000ES, but proper configuration is key to resolving these errors.

Recommended Configuration Steps
Here’s how to configure your system:

1. Physical Connections
Battery to Inverter: Ensure the battery power cables (positive and negative) are securely connected to the inverter’s battery terminals, with no loose connections or corrosion.
Communication Cable: The Hope 5.5L-A1 typically uses a CAN bus for BMS communication. Connect an RJ45 cable between the battery’s CAN port and the inverter’s BMS port. Use the cable provided by Growatt, as pin assignments matter (e.g., CAN-H and CAN-L must match).
Battery Breaker: Confirm the battery breaker is ON and the battery is outputting power.

2. Check Battery Voltage
Use a multimeter to measure the battery voltage at the terminals. The Hope 5.5L-A1 is a 48V nominal battery, so a healthy voltage should be between 48V and 54V (depending on SOC). If it’s below 42V, it may need charging via solar or grid before the inverter can operate properly.

3. Inverter Settings
Access the SPF 6000ES settings via the LCD display and buttons. Adjust the following parameters (refer to the SPF 6000ES manual for navigation):
Program 05 (Battery Type): Set to “LI” (Lithium) to enable BMS communication. Since the Hope 5.5L-A1 is a Growatt battery, select the appropriate lithium protocol:

Likely L01 or L03 (specific to Growatt ARK/Hope series). Check the battery manual or Growatt to confirm the exact protocol code for the 5.5L-A1.

Avoid “USE” or “US2” unless BMS communication fails entirely (more on this later).
Program 02 (Max Charging Current): Set to a safe value, e.g., 60A-100A, depending on your battery’s specs (Hope 5.5L-A1 typically s up to 100A charging).
Program 01 (Output Source Priority): Set to “SBU” (Solar-Battery-Utility) or “SUB” (Solar-Utility-Battery) based on your preference.
Program 12 (Battery Low Voltage Cutoff): Set to 42V-44V to prevent deep discharge.
Program 13 (Battery Back-to-Grid Voltage): Set to 48V-50V to ensure the battery charges adequately.
Program 19 (CV Charging Voltage): Set to 56.4V (default for most 48V lithium batteries, including Growatt’s).
Program 20 (Float Charging Voltage): Set to 54V or as recommended by the Hope 5.5L-A1 manual.

4. Test BMS Communication
After setting Program 05 to “LI” with the correct protocol, restart the inverter by turning it off and back on.
Check the LCD for battery SOC and voltage readings. If Error 20 disappears and SOC displays correctly, communication is established.

5. Troubleshooting Errors

If errors persist:
Error 04 Persists:
The battery may be too discharged. Charge it externally (via solar s or a charger) until it reaches at least 48V, then reconnect.
the inverter’s voltage reading matches your multimeter. If not, there may be a wiring issue or inverter fault.

Error 20 Persists:
Double-check the RJ45 cable integrity. Swap it with a known working cable if possible.
Ensure the battery’s firmware and inverter’s firmware are up to date and compatible. Growatt for the latest firmware if needed.
As a fallback, set Program 05 to “US2” (-Defined without BMS). This disables BMS communication and relies on voltage-based control. Adjust Programs 19 and 20 as above, but this is less optimal for battery health.

6. Additional Checks
Battery Health: If the Hope 5.5L-A1 has been deeply discharged repeatedly, it might be in a protection mode. Reset it per the battery manual (usually involves turning it off/on or pressing a reset button).
Inverter Logs: Review the inverter’s fault log (if accessible) for more context on when Errors 04 and 20 trigger.

Next Steps
Try these steps and monitor the system. If Errors 04 and 20 still occur, let me know:
The exact battery voltage you measure.
Whether the BMS communication works after setting “LI” with the correct protocol.
Any additional behavior (e.g., inverter shutting down, alarms).
This should resolve the issue, but if not, we can dig deeper into hardware or firmware causes. Let me know how it goes!
Why did you say avoid use 2, is it for his specific problem or generally??
maklelemakukula(m): 4:28pm On Feb 28
kristien4:
Why did you say avoid use 2, is it for his specific problem or generally??
AI told me so bro. I, a mere mortal, am not very knowledgeable in this field

1 Like

HeavenlyBang(m): 5:00pm On Feb 28
Nteogwuija:
Hi, guys. So I did a parallel connection of 3 350w s, with each having a maximum current of 13.6a. And I've noticed that whenever the sun is very high my DC breaker would go off and the system will stop charging. I'd have to turn it back on b4 it resumes charging.

The wire is a 4mm² coated wire.

Please, what do I have to change to rectify this?

1. You're running a 40A connection? What charge controller is that?

2. 40A DC requires ~8mm wire at least.

Reply)